TEST BENCHES
TSHF 450 NN
Delta P Filters
The TSHF 450 NN filter test bench is provided with two independent stations and it performs filter tests in compliance with the ISO3968 standards.
TECHNICAL DATA
• Maximum operating working 450 lt/min
• Minimum operating working 5 lt/min
• Maximum operating pressure 25 bar (295 PSI)
• Maximum operating temperature 150°C (302° F)
• Minimum operating temperature 20 °C (68° F)
• Maximum operating viscosity 130 cst
• Minimum operating viscosity 3 cst
SAFETY
• Interlock avoid to run the test with open hatch
• Openings in polycarbonate for displaying the elements being tested
• Emergency button
• Automatic interruption for any malfunctions of the bench
POWER SUPPLY
• Standard voltage of 400 V – 50 Hz – three-phase (special voltages on request)
OPTIONAL
• System for introducing, controlling and measuring 2% contaminated water in the main circuit • High precision volumetric flow device